Please use this identifier to cite or link to this item: http://hdl.handle.net/11422/15555
Type: Trabalho de conclusão de especialização
Title: O desempenho da medida do índice de pulsatibilidade do ducto venoso na predição de desfechos gestacionais adversos
Author(s)/Inventor(s): Marques, Juliana Laponte
Advisor: Rezende, Karina Bilda de Castro
Abstract: Introdução: A alteração do Ducto venoso (DV) qualitativa ou quantitativamente concorre com prognóstico adverso da gestação, como a presença de anomalias estruturais, síndromes genéticas e óbito fetal. Objetivos: Descrever a distribuição do Índice de pulsatibilidade do ducto venoso (PI-DV) e verificar a associação da mensuração do mesmo com o óbito fetal sem causa aparente, presença de alterações cromossômicas no feto e/ou recém-nascido (RN) e com a presença de malformações no feto e/ou RN. Métodos: Estudo transversal, descritivo e analítico. Foram incluídos todos casos consecutivos de gestações únicas, que realizaram ultrassonografia (USG) com a mensuração de PI-DV, no período de 01 de janeiro de 2013 a 31 de dezembro de 2015, com desfecho conhecido da gestação. Foi construída curva ROC (receiver operator characteristic) para determinar o desempenho do teste, para cada um dos possíveis desfechos estudados. Resultados: Tivemos 1047 casos na amostra final do estudo com os seguintes desfechos: 17 óbitos fetais, sendo 11 antes de 24 semanas e 6 entre 25 e 40 semanas, 19 fetos com malformações identificadas pela USG, das quais 5 foram cardiopatias e 2 fetos com alterações cromossômicas identificadas pelo cariótipo. Obtivemos o percentil 95 do grupo normal, que foi 1,35 (IC95%:1,32-1,44). Discussão: O rastreio do primeiro trimestre na Maternidade Escola da Universidade Federal do Rio de Janeiro é feito pelo programa Astraia ®, a partir dos dados da idade materna, medida do PI-DV e da TN. Não utilizamos os marcadores bioquímicos (PAPP-A, βHCG- livre), pelo custo elevado. Apesar de apenas 2 casos de aneuploidias confirmadas em nossa amostra, nossa casuística obteve significativa associação com o aumento do PI-DV, seguindo os resultados mostrados pela literatura. Encontramos semelhança ao avaliarmos o percentil 95 do PI-DV, com outros autores que também avaliaram nossa população. Conclusões: A medida do PI-DV, na amostra estudada, teve boa associação com a ocorrência de alterações cromossômicas.
Abstract: Introduction: Alteration of the ductus venosus (DV), qualitatively or quantitatively, contributes to the adverse prognosis of pregnancy, such as the presence of structural abnormalities, genetic syndromes and fetal death. Objectives: To describe the distribution of ductus venosus pulsatibility index (PI-DV) and to verify the association of the measurement of the same with fetal death without apparent cause, presence of chromosomal changes in the fetus and / or newborn (NB) and with the presence of malformations in the fetus and / or RN. Methods: Cross - sectional, descriptive and analytical study. A total of 1047 cases of single pregnancies, which performed ultrasonography (USG) with the measurement of PI-DV, were enrolled between January 1, 2013 and December 31, 2015, with a known outcome of gestation. Receiver operator characteristic (ROC) curve was constructed to determine the performance of the test, to define the value for which the sensitivity of the test with false positive rate was verified and to perform a logistic regression analysis for each of the possible outcomes studied. Results: We had 1047 cases in the final sample of the study with the following outcomes: 17 fetal deaths, 11 before 24 weeks and 6 between 25 and 40 weeks, 19 fetuses with malformations identified by USG, of which 5 were heart diseases and 2 fetuses with Chromosome changes identified by the karyotype. We obtained the 95th percentile of the normal group, which was 1.35 (95% CI: 1.32-1.44). Discussion: The first trimester screening in the Maternidade Escola of the Federal University of Rio de Janeiro is done by the Astraia ® calculation, with data on maternal age, PI-DV measurement and NT measurement. We did not use biochemical markers (PAPP-A, βHCG-free) at high cost. In spite of only 2 confirmed cases of aneuploidies in our sample, our series had a significant association with the increase in PI-DV, following the results shown in the literature. We found similarity when we evaluated the 95th percentile of PI-DV, with other authors who also evaluated our population. Conclusions: The measurement of PI-DV in the sample studied was well associated with the occurrence of chromosomal alterations and did not present any association with the occurrence of fetal death and malformations.
Keywords: Ducto venoso
Transtornos cromossômicos
Diagnóstico pré-natal
Duct venosus
Chromosome disorders
Prenatal diagnosis
Subject CNPq: CNPQ::CIENCIAS DA SAUDE::MEDICINA::SAUDE MATERNO-INFANTIL
Program: Programa de Residência Multiprofissional em Saúde Perinatal
Production unit: Maternidade Escola
Publisher: Universidade Federal do Rio de Janeiro
Issue Date: Feb-2017
Publisher country: Brasil
Language: por
Right access: Acesso Aberto
Citation: MARQUES, Juliana Lapoente. O desempenho da medida do índice de pulsatibilidade do ducto venoso na predição de desfechos gestacional adversos. 2017. 36 f. Trabalho de conclusão de curso (Especialização em Saúde Perinatal) - Maternidade Escola, Universidade Federal do Rio de Janeiro, Rio de Janeiro, 2017.
Appears in Collections:Saúde Perinatal

Files in This Item:
File Description SizeFormat 
JLMarques.pdf445.66 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.