Please use this identifier to cite or link to this item: http://hdl.handle.net/11422/14040
Type: Dissertação
Title: Detecção de faltas de alta impedância em sistemas de distribuição de energia elétrica
Other Titles: High impedance fault detection in electrical power distribution systems
Author(s)/Inventor(s): Ferreira, Gabriel de Alvarenga
Advisor: Assis, Tatiana Mariano Lessa de
Abstract: [PT] No Brasil, a distribuição de energia elétrica é predominantemente realizada a partir de ramais aéreos, sem isolamento. Apesar de mais baratos, esses sistemas estão mais suscetíveis à ocorrência de faltas (curtos-circuitos). Dentre essas faltas, as Faltas de Alta Impedância (FAIs) ainda representam um grande desafio em relação à sua detecção, visto que, entre outras características específicas, os baixos níveis de corrente de falta gerados por esses eventos não sensibilizam os esquemas de proteções convencionais desses sistemas, amplamente baseados em relés de sobrecorrente. Neste cenário, este trabalho tem como objetivo principal um amplo estudo em relação à detecção de FAIs em sistemas de distribuição. Após a realização de uma larga revisão bibliográfica e a definição dos métodos mais relevantes, de acordo com alguns critérios de importância, dois destes métodos são escolhidos para simulação. Adicionalmente, um novo método baseado em Transformada Discreta de Wavelet é proposto. Após a apresentação detalhada dos métodos e da metodologia utilizada para as simulações no software PSCAD, são também apresentados os resultados e discussões referentes aos casos de simulação. Ao final, são apresentadas as conclusões e realizadas proposições para trabalhos futuros.
Abstract: [EN] In Brazil, the distribution of electric power is predominantly performed by the use of aerial branches, without isolation. Although cheaper, these systems are more susceptible to the occurrence of faults (short circuits). Among these faults, High Impedance Faults (HIFs) still represent a major challenge regarding their detection, since, among other specific characteristics, the low fault current levels generated by these events do not sensitize the conventional protection schemes of these systems, largely based on overcurrent relays. In this scenario, this work has as main objective a broad study in relation to the detection of HIFs in distribution systems. After a large bibliographic review and the definition of the most relevant methods, according to some criteria of importance, two of these methods are chosen for simulation. Additionally, a new method based on Discrete Wavelet Transform is proposed. After the detailed presentation of the methods and methodology used for the simulations in the PSCAD software, the results and discussions regarding the simulation cases are also presented. Finally, the conclusions and proposals for future works are presented.
Keywords: Detecção de faltas de alta impedância
Sistemas elétricos de distribuição
Proteção de sistemas elétricos de potência
Subject CNPq: CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA
Program: Programa de Pós-Graduação em Engenharia Elétrica
Production unit: Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia
Publisher: Universidade Federal do Rio de Janeiro
Issue Date: Oct-2019
Publisher country: Brasil
Language: por
Right access: Acesso Aberto
Appears in Collections:Engenharia Elétrica

Files in This Item:
File Description SizeFormat 
GabrielDeAlvarengaFerreira-min.pdf2.93 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.