Title: Aplicação de fasores dinâmicos na localização de defeitos em linhas de transmissão aéreas
Author(s)/Inventor(s): Costa, Thassiana Batista da
Advisor: Lima, Antonio Carlos Siqueira de
Co-advisor: Dias, Robson Francisco da Silva
Abstract: Esta tese propõe o emprego de um fasor dinâmico para a detecção e localização de defeitos em linhas de transmissão aéreas e em cabos subterrâneos. Ao invés de utilizar a formulação tradicional do fasor dinâmico baseado na modulação em amplitude, esta tese propõe a utilização de uma formulação baseada na modulação em frequência, uma vez que esta aumenta os sinais transitórios associados ao defeito. A modulação em frequência foi sintetizada a partir de sinais obtidos de um circuito PLL (Phase-Locked Loop). Assim, a fim de investigar a adequação do PLL para esta tarefa, foi realizado um teste inicial considerando o PLL como uma PMU (Phasor Measurement Unit). Posteriormente, o PLL foi implementado em um DSP (Digital Signal Processor). Vários testes, incluindo ambientes poluídos por harmônicos, foram usados para avaliar o desempenho do PLL. O algoritmo baseado na modulação de frequência foi, então, testado para a localização da falta de alta impedância, uma vez que eles tendem a apresentar baixa observabilidade e permanecem um desafio para várias redes reais. Os resultados indicam a adequação do esquema proposto, pois o algoritmo conseguiu manter um nível adequado de precisão, independentemente da falha considerada.
Abstract: This thesis proposes a method based on dynamic phasor for the detection and location of fault in overhead lines and underground cables. Instead of using the traditional formulation of the dynamic phasor based on amplitude modulation, this thesis proposes to use a formulation based on frequency modulation, as it was found that the frequency modulation increases the transient signals associated with the fault, thus improving its detectability. The frequency modulation was synthesized based on the signals obtained by a PLL (Phase-Locked Loop) circuit. Thus, in order to investigate the adequacy of the PLL for this task, an initial test considering the PLL as a PMU (Phasor Measurement Unit) was performed. Then, the PLL was also implemented in a DSP (Digital Signal Processor). Several test cases including harmonic polluted environments were used to evaluate the performance of the PLL as a PMU. The algorithm based on the frequency modulation was then tested for the high impedance fault location, as they tend to present low observability and remain a challenge for several actual networks. The results indicate the adequacy of the proposed scheme as the algorithm was able to maintain a suitable level of accuracy, regardless of the fault considered.Também disponível on-line.
Keywords: Localização de faltas
Alta impedância
Linhas de transmissão
Sintetizador
Subject CNPq: CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA::SISTEMAS ELETRICOS DE POTENCIA
Program: Programa de Pós-Graduação em Engenharia Elétrica
Production unit: Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia
Publisher: Universidade Federal do Rio de Janeiro
Issue Date: Mar-2019
Publisher country: Brasil
Language: por
Right access: Acesso Aberto