Please use this identifier to cite or link to this item: http://hdl.handle.net/11422/27544

Type: Dissertação
Title: Alterações cardíacas em crianças e adolescentes diagnosticados com síndrome inflamatória multissistêmica pediátrica relacionada à COVID-19
Author(s)/Inventor(s): Panizzi, Thiago Taucei
Advisor: Bravo-Valenzuela, Nathalie Jeanne Magioli
Co-advisor: Fonseca, Adriana Rodrigues
Co-advisor: Sztajnbok, Flavio Roberto
Abstract: Introdução: A síndrome inflamatória multissistêmica pediátrica (SIM-P), associada à infecção pelo SARS-CoV-2, é amplamente reconhecida pelo seu potencial de comprometimento cardiovascular, o que reforça a necessidade de uma avaliação cardiológica abrangente na fase aguda e de um seguimento prolongado para melhor compreender sua evolução, impacto cardiovascular e possíveis complicações futuras. Objetivos: Descrever os dados epidemiológicos, as manifestações clínicas, as alterações laboratoriais, o tratamento instituído e os achados ao eletrocardiograma e ecocardiograma em crianças e adolescentes diagnosticados com síndrome inflamatória multissistêmica pediátrica (SIM-P), bem como descrever os achados ecocardiográficos nos primeiros 12 meses de evolução e de ecocardiograma com Strain Longitudinal Global do Ventrículo Esquerdo (SLG-VE) três anos após o diagnóstico inicial. Materiais e Métodos: Estudo de coorte retrospectivo e prospectivo, observacional, longitudinal e descritivo com análise exploratória, incluindo crianças e adolescentes de 0 até 18 anos diagnosticados com SIM-P, de acordo com os critérios da OMS, atendidos em um centro universitário especializado, entre março de 2020 até dezembro de 2024. Foram analisados dados demográficos, manifestações clínicas, exames laboratoriais, microbiológicos, eletrocardiogramas e ecocardiogramas. Os exames de ecocardiografia transtorácica foram analisados à admissão e com 12 meses do diagnóstico. Os exames de ecocardiografia com SLG-VE foram realizados três anos após o diagnóstico. A análise estatística foi descritiva, com frequências absolutas e percentuais para variáveis categóricas, além de médias e desvios-padrão ou medianas e intervalo interquartil para as variáveis contínuas. Foram comparados os pacientes com e sem alterações cardiovasculares. As diferenças entre proporções dos dois grupos foram calculadas pelo Teste exato de Fisher, Teste do Qui-quadrado ou Teste de Wilcoxon rank-sum. A diferença foi considerada estatisticamente significativa quando p < 0,05. Foi utilizado o teste T para comparação dos parâmetros fração de ejeção do ventrículo esquerdo (FEVE) e Z score das artérias coronárias. Para avaliar a padronização e a acurácia das medições, realizamos a correlação intraclasse (ICC - Intraclass Correlation Coefficient) no modelo Two-Way Random Effects para verificar a concordância intra-observador e inter-observadores de amostras de medidas do diâmetro das artérias coronárias (20% da amostra total). Resultados: Incluídos 36 pacientes, com mediana de idade ao diagnóstico de 2,15 anos (IQR 3,3), predomínio do sexo masculino (69,4%). Na admissão, 41,7% dos pacientes apresentaram alterações cardiovasculares detectadas clinicamente ou por ecocardiograma, sendo 10 de origem clínica, 2 de imagem e 3 associando ambas. No seguimento de 1 ano, 22 pacientes foram reavaliados clínica e ecocardiograficamente, não sendo observadas alterações; entretanto, entre eles, 5 já apresentavam alteração clínica à admissão, 2 alteração de imagem e 3 associação clínica e de imagem. Na terceira fase, realizada três anos após o diagnóstico, 11 pacientes foram submetidos a ecocardiograma com análise do SLG-VE, sendo que 4 apresentavam previamente alteração clínica e 1 alteração de imagem na admissão. Em 10 dos 11 pacientes avaliados, o SLG-VE demonstrou disfunção subclínica não identificada pelo eletrocardiograma ou pelo ecocardiograma convencional. Conclusão: As alterações cardiovasculares clínicas ou ecocardiográficas foram frequentes na fase aguda da SIM-P. Na coorte estudada, nenhum paciente apresentou alterações na função cardíaca nos exames ecocardiográficos de 1 ano quando avaliados pelos métodos tradicionais. Nesse contexto, a análise do SLG-VE por ecocardiografia com speckle tracking tem se mostrado uma ferramenta sensível e promissora para a identificação de disfunções miocárdicas subclínicas, que não seriam detectadas por parâmetros como a FEVE. Por isso, o acompanhamento a longo prazo desses pacientes é fundamental, uma vez que algumas alterações subclínicas podem persistir ou evoluir com o tempo, permitindo a detecção precoce de disfunção cardíaca residual, a prevenção de complicações tardias e a implementação de intervenções terapêuticas apropriadas para reduzir o risco cardiovascular futuro.
Abstract: Introduction: Pediatric multisystem inflammatory syndrome (MIS-C), associated with SARS-CoV-2 infection, is widely recognized for its potential cardiovascular involvement, highlighting the need for comprehensive cardiac assessment in the acute phase and prolonged follow-up to better understand its progression, cardiovascular impact, and possible future complications. Objectives: To describe the epidemiological data, clinical manifestations, laboratory abnormalities, treatment provided, and electrocardiographic and echocardiographic findings in children and adolescents diagnosed with multisystem inflammatory syndrome in children (MIS-C). Additionally, to report echocardiographic findings during the first 12 months of follow-up and Left Ventricular Global Longitudinal Strain (LV-GLS) measurements on echocardiography three years after the initial diagnosis. Materials and Methods: A retrospective and prospective, observational, longitudinal, and descriptive with exploratory analysis cohort study was conducted, including children and adolescents aged 0 to 18 years diagnosed with MIS-C according to WHO criteria, treated at a specialized university center between March 2020 and December 2024. Demographic data, clinical manifestations, laboratory and microbiological tests, electrocardiograms, and echocardiograms were analyzed. Transthoracic echocardiograms were performed at admission and at 12 months after diagnosis. Echocardiographic assessments with LV-GLS were performed three years after diagnosis. Statistical analysis was descriptive, using absolute and relative frequencies for categorical variables, and means with standard deviations or medians with interquartile ranges for continuous variables. Patients with and without cardiovascular abnormalities were compared. Differences in proportions between the two groups were assessed using Fisher's exact test, Chi-squared test, or Wilcoxon rank-sum test. A p-value < 0.05 was considered statistically significant. The T-test was used to compare left ventricular ejection fraction (LVEF) and coronary artery Z-scores. To assess measurement standardization and accuracy, the intraclass correlation coefficient (ICC) was calculated using a two-way random-effects model to evaluate intra- and interobserver agreement for coronary artery diameter measurements (20% of the total sample). Results: Thirty-six patients were included, with a median age at diagnosis of 2.15 years (IQR 3.3), and a predominance of males (69.4%). At admission, 41.7% of patients presented cardiovascular abnormalities detected clinically or by echocardiography, including 10 of clinical origin, 2 imaging, and 3 combining both. At the 1-year follow-up, 22 patients were reassessed clinically and by echocardiography, with no abnormalities observed; however, among them, 5 had shown clinical alterations at admission, 2 imaging alterations, and 3 both clinical and imaging alterations. In the third phase, conducted three years after diagnosis, 11 patients underwent echocardiography with analysis of LV-GLS, of whom 4 had previously presented clinical alterations and 1 an imaging alteration at admission. In 10 of the 11 patients evaluated, LV-GLS demonstrated subclinical dysfunction not identified by electrocardiography or conventional echocardiography. Conclusion: Clinical and echocardiographic cardiovascular abnormalities are common findings in the acute phase of MIS-C. In the studied cohort, no patients showed alterations in cardiac function at the 1-year echocardiographic follow-up when assessed by conventional methods. In this context, LV-GLS analysis using speckle-tracking echocardiography has proven to be a sensitive and promising tool for identifying subclinical myocardial dysfunction that would not be detected by parameters such as LVEF. Therefore, long-term follow-up of these patients is essential, as some subclinical alterations may persist or progress over time, allowing for early detection of residual cardiac dysfunction, prevention of late complications, and implementation of appropriate therapeutic interventions to reduce future cardiovascular risk.
Keywords: COVID-19
Síndromes periódicas associadas à criopirina
Anormalidades cardiovasculares
Circulação coronária
Ecocardiografia
Deformação longitudinal global
Subject CNPq: CNPQ::CIENCIAS DA SAUDE::MEDICINA::SAUDE MATERNO-INFANTIL
Program: Programa de Pós-Graduação em Saúde Materno-Infantil
Production unit: Instituto de Puericultura e Pediatria Martagão Gesteira
Publisher: Universidade Federal do Rio de Janeiro
Issue Date: 28-Aug-2025
Publisher country: Brasil
Language: por
Right access: Acesso Aberto
Citation: PANIZZI, Thiago Taucei. Alterações cardíacas em crianças e adolescentes diagnosticados com síndrome inflamatória multissistêmica pediátrica relacionada à COVID-19. Dissertação (Mestrado em Saúde Materno-Infantil) - Instituto de Puericultura e Pediatria Martagão Gesteira, Universidade Federal do Estado do Rio de Janeiro, Rio de Janeiro, 2025.
Appears in Collections:Saúde Materno-Infantil

Files in This Item:
File Description SizeFormat 
TTPanizzi.pdf7.67 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.