Please use this identifier to cite or link to this item:
http://hdl.handle.net/11422/29137
| Type: | Dissertação |
| Title: | Avaliação de glifosato e ácido aminometilfosfônico (AMPA) Em urina de gestantes e puérperas na cidade do Rio de Janeiro por cromatografia líquida de alta eficiência acoplada a detector de fluorescência (CLAE-FLD) |
| Other Titles: | Evaluation of glyphosate and aminomethylphosphonic acid (AMPA) in urine samples from pregnant and postpartum women in the city of Rio de Janeiro by high-performance liquid chromatography coupled with fluorescence detection (HPLC-FLD) |
| Author(s)/Inventor(s): | Oliveira, Heldis Beloni de |
| Advisor: | Padilha, Monica Costa |
| Co-advisor: | Rosa, Ana Cristina Simões |
| Abstract: | O glifosato é um agrotóxico amplamente utilizado no Brasil e no mundo, cuja presença em matrizes ambientais e biológicas tem despertado interesse científico, especialmente no contexto de estudos de biomonitoramento humano. Nesse sentido, o presente trabalho teve como objetivo desenvolver, otimizar, validar e aplicar um método analítico para a determinação de glifosato e de seu principal metabólito, o ácido aminometilfosfônico (AMPA), em amostras de urina de gestantes. O método baseia-se na cromatografia líquida de alta eficiência acoplada a detector de fluorescência (CLAE-FLD), com derivatização com cloreto de 9-fluorenilmetoxicarbonil (FMOC-Cl). O preparo das amostras envolveu etapas de limpeza por extração líquido-líquido, derivatização e extração em fase sólida, as quais foram sistematicamente otimizadas quanto aos solventes, volumes, tempo e temperatura de reação. A validação do método foi conduzida de acordo com diretrizes nacionais e internacionais, incluindo as normativas estabelecidas pelo Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO), avaliando-se os parâmetros de seletividade, linearidade, limites de detecção e quantificação, precisão, exatidão, repetibilidade e precisão intermediária. O método apresentou comportamento linear na faixa de concentração estudada, ausência de efeito matriz significativo, limites de detecção de 0,03 μg L⁻¹ e limite de quantificação de 0,11 μg L⁻¹ para o glifosato, bem como limite de detecção de 0,15 μg L⁻¹ e limite de quantificação de 0,50 μg L⁻¹ para o AMPA, limites de detecção compatíveis com aplicações em biomonitoramento e recuperações médias superiores a 90% para ambos os analitos, variando de 107–109% para o glifosato e de 97–100% para o AMPA, com baixos valores de desvio padrão relativo. Após a validação, o método foi aplicado à análise de 10 amostras de urina de gestantes residentes no estado do Rio de Janeiro. As concentrações de glifosato e AMPA nas amostras analisadas encontraram-se abaixo dos limites de detecção do método. O desempenho analítico em matriz real foi confirmado por meio de controles positivos por fortificação a 2,5 μg L⁻¹, que apresentaram recuperações médias de 99,4% para o glifosato e 96,4% para o AMPA. Os resultados obtidos demonstram que o método desenvolvido é adequado para a determinação de glifosato e AMPA em urina, apresentando potencial aplicação em estudos de biomonitoramento humano. |
| Abstract: | Glyphosate is a pesticide widely used in Brazil and worldwide, whose presence in environmental and biological matrices has raised scientific interest, particularly in the context of human biomonitoring studies. In this regard, the present study aimed to develop, optimize, validate, and apply an analytical method for the determination of glyphosate and its main metabolite, aminomethylphosphonic acid (AMPA), in urine samples from pregnant women. The method is based on high-performance liquid chromatography coupled with a fluorescence detector (HPLC-FLD), following derivatization with 9-fluorenylmethoxycarbonyl chloride (FMOC-Cl). Sample preparation involved liquid–liquid extraction clean-up, derivatization, and solid-phase extraction steps, which were systematically optimized in terms of solvents, volumes, reaction time, and temperature. Method validation was carried out in accordance with national and international guidelines, including the Brazilian National Institute of Metrology, Quality and Technology (INMETRO), evaluating selectivity, linearity, limits of detection and quantification, precision, accuracy, repeatability, and intermediate precision. The method showed linear behavior over the concentration range of 0.5–10 μg L⁻¹ for both analytes, no significant matrix effect, and limits of detection of 0.03 μg L⁻¹ for glyphosate and 0.15 μg L⁻¹ for AMPA, with limits of quantification of 0.11 μg L⁻¹ and 0.50 μg L⁻¹, respectively. Recovery assays performed at different concentration levels within the established linear range yielded recoveries between 107–109% for glyphosate and 97–100% for AMPA, with low relative standard deviation values. After validation, the method was applied to the analysis of 10 urine samples from pregnant women residing in the state of Rio de Janeiro, Brazil. Glyphosate and AMPA concentrations in all analyzed samples were below the method detection limits. The analytical performance in real matrix was confirmed by fortified control samples at 2.5 μg L⁻¹, which demonstrated the robustness and reliability of the method. These results indicate that the developed method is suitable for the determination of glyphosate and AMPA in urine and presents strong potential for application in human biomonitoring studies. |
| Keywords: | Glifosato Biomonitoramento humano CLAE-FLD Gestantes AMPA Ácido Aminometilfosfônico Cromatografia líquida de alta eficiência acoplada a detector de fluorescência |
| Subject CNPq: | CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA::QUIMICA ANALITICA::METODOS OTICOS DE ANALISE |
| Program: | Programa de Pós-Graduação em Química |
| Production unit: | Instituto de Química |
| Publisher: | Universidade Federal do Rio de Janeiro |
| Issue Date: | 27-Feb-2026 |
| Publisher country: | Brasil |
| Language: | por |
| Right access: | Acesso Aberto |
| Citation: | OLIVEIRA, Heldis Beloni de. Avaliação de glifosato e ácido aminometilfosfônico (AMPA) Em urina de gestantes e puérperas na cidade do Rio de Janeiro por cromatografia líquida de alta eficiência acoplada a detector de fluorescência (CLAE-FLD). 2026. 160 f. Dissertação (Mestrado) - Curso de Química, Instituto de Química, Universidade Federal do Rio de Janeiro, Rio de Janeiro, 2026 |
| Appears in Collections: | Química |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| HBOliveira.pdf | 2.98 MB | Adobe PDF | View/Open ???org.dspace.app.webui.jsptag.ItemTag.restrict??? |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.