Please use this identifier to cite or link to this item:
http://hdl.handle.net/11422/29531
| Type: | Trabalho de conclusão de especialização |
| Title: | Características clínicas, controle glicêmico e qualidade de vida em pacientes usando sistemas de pâncreas artificial Android AAPS® no Brasil |
| Author(s)/Inventor(s): | Ventura, Gabriella Lopes |
| Advisor: | Rodacki, Melanie |
| Abstract: | Este estudo avaliou a segurança e a eficácia do sistema Android Artificial Pancreas System (AAPS) em indivíduos brasileiros com diabetes mellitus tipo 1 (DM1). Foram incluídos 371 participantes, sendo 62 usuários do AAPS e 309 não usuários. As configurações utilizadas pelos usuários do AAPS incluíram o monitor contínuo de glicose (CGM) de primeira geração, transmissor Bluetooth (MiaoMiao) e bomba de insulina não automatizada. Os usuários do AAPS apresentaram tempo no alvo glicêmico (Time in Range – TIR) médio de 78,5% ± 16,6, com redução significativa dos níveis de hemoglobina glicada (HbA1c) de 7,3% ± 1,03 para 6,5% ± 0,7 (p < 0,001). Em comparação aos não usuários, o grupo AAPS demonstrou melhor controle glicêmico, menor frequência de episódios de hipoglicemia grave (p = 0,006) e melhor qualidade de vida (p < 0,0001). Apesar disso, 23,08% dos usuários apresentaram TIR inferior a 70%, e o tempo em hipoglicemia nível 2 excedeu as recomendações atuais. Esses resultados indicam que o AAPS é uma alternativa de baixo custo aos sistemas automatizados comerciais, com potencial para ampliar o acesso à terapia automatizada de insulina, especialmente em países com recursos limitados. Observou-se que, mesmo utilizando uma configuração de dispositivos de menor custo, os usuários do AAPS alcançaram parâmetros de controle glicêmico compatíveis com as metas recomendadas para indivíduos com DM1. A melhora observada na HbA1c e na qualidade de vida reforça a viabilidade clínica e o impacto positivo do uso do AAPS na rotina de pacientes brasileiros. Contudo, o fato de parte dos usuários apresentar controle glicêmico subótimo sugere a necessidade de acompanhamento médico adequado e orientação técnica durante a instalação e o uso do sistema. Assim, o AAPS desponta como uma opção promissora e acessível para o manejo automatizado do diabetes tipo 1, contribuindo para a redução das desigualdades no acesso à tecnologia em saúde. |
| Abstract: | This study evaluated the safety and efficacy of the Android Artificial Pancreas System (AAPS) in Brazilian individuals with type 1 diabetes mellitus (T1D). A total of 371 participants were included, comprising 62 AAPS users and 309 non-users. The AAPS configurations used included a first-generation continuous glucose monitor (CGM), a Bluetooth transmitter (MiaoMiao), and a non-automated insulin pump. AAPS users achieved a mean Time in Range (TIR) of 78.5% ± 16.6, with a significant reduction in glycated hemoglobin (HbA1c) from 7.3% ± 1.03 to 6.5% ± 0.7 (p < 0.001). Compared with non-users, the AAPS group demonstrated better glycemic control, fewer severe hypoglycemic episodes (p = 0.006), and improved quality of life (p < 0.0001). Nevertheless, 23.08% of users had a TIR below 70%, and time spent in level-2 hypoglycemia exceeded current recommendations. These findings indicate that AAPS is a low-cost alternative to commercial automated systems, with the potential to expand access to automated insulin therapy, particularly in resource-limited settings. Despite relying on more affordable device configurations, AAPS users achieved glycemic parameters consistent with recommended targets for individuals with T1D. The observed improvements in HbA1c and quality of life reinforce the clinical feasibility and positive impact of AAPS use in Brazilian patients. However, the presence of suboptimal glycemic control among some users highlights the importance of appropriate medical follow-up and technical guidance during system setup and use. Therefore, AAPS emerges as a promising and accessible option for automated management of type 1 diabetes, contributing to the reduction of inequalities in access to health technology. |
| Keywords: | Diabetes mellitus tipo 1 Controle glicêmico Tecnologia biomédica Type 1 diabetes mellitus Glycemic control Biomedical technology |
| Subject CNPq: | CNPQ::CIENCIAS DA SAUDE::MEDICINA::CLINICA MEDICA |
| Program: | Programa de Residência Médica |
| Production unit: | Hospital Universitário Clementino Fraga Filho |
| Publisher: | Universidade Federal do Rio de Janeiro |
| Issue Date: | Dec-2025 |
| Publisher country: | Brasil |
| Language: | por |
| Right access: | Acesso Aberto |
| Citation: | VENTURA, Gabriella Lopes. Características clínicas, controle glicêmico e qualidade de vida em pacientes usando sistemas de pâncreas artificial Android AAPS® no Brasil. Orientadora: Melanie Rodacki. 2025. 16 f. Trabalho de Conclusão de Curso (Residência Médica em Clínica Médica) – Hospital Universitário Clementino Fraga Filho, Universidade Federal do Rio de Janeiro, Rio de Janeiro, 2025. |
| Appears in Collections: | Clínica Médica |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| GLVentura.pdf | 196.59 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.