Please use this identifier to cite or link to this item:
http://hdl.handle.net/11422/10156
Type: | Dissertação |
Title: | Modelagem por partes da cinética da resposta cronotrópica cardíaca durante a caminhada em esteira ergométrica |
Author(s)/Inventor(s): | Afonso, Renata Maria Begni |
Advisor: | Tavares, Frederico Caetano Jandre de Assis |
Co-advisor: | Nadal, Jurandir |
Abstract: | O objetivo deste estudo foi modelar as variações dos intervalos entre um pico R e outro (IRR) do eletrocardiograma (ECG) em resposta a degraus de velocidade durante a caminhada, por meio de um modelo exponencial de primeira ordem. Vinte e cinco homens, jovens e saudáveis, realizaram o protocolo de teste compreendido por: 1 min de repouso, seguido por 2 min de aquecimento a 3 km/h e quatro degraus, com 4 min de duração para as velocidades de 5 km/h, 7 km/h, 5 km/h e 0 km/h. O sinal de IRR foi adquirido continuamente por meio de um eletrocardiógrafo e um cardiofrequencímetro. Aplicou-se o método Nelder Mead Simplex para ajustar a constante de tempo (𝜏) e o ganho (𝑘) do modelo aos valores reais de IRR em cada degrau, de modo que a curva dos degraus subsequentes foram somadas às anteriores. O ajuste obteve R2 = 0,9 (0,85-0,92) e valores de 𝜏 e 𝑘 estatisticamente diferentes entre os degraus, com p << 0,05. Tais resultados indicam que o modelo é capaz de descrever a FC durante a caminhada em diferentes velocidades e que a sua dinâmica, em exercício submáximo, é não linear, posto que degraus de mesmo valor apresentaram respostas diferentes. |
Abstract: | The objective of this study was to model the variations in the intervals between a R-peak and another (IRR) of the electrocardiogram (ECG) in response to walking steps through an exponential first order model. Twenty-five men, young and healthy, performed the test protocol comprised of: 1 min of rest, followed by 2 min of warming up at 3 km / h and four steps, with 4 min of duration at speeds of 5 km / h, 7 km / h, 5 km / h and 0 km / h. The IRR signal was acquired continuously by means of an electrocardiograph and a cardiofrequency meter. The Nelder Mead Simplex method was applied to adjust the time constant (τ) and the gain (k) of the model to the actual IRR values in each step, so that the subsequent steps curve were added to the previous ones. The adjustment obtained R2 = 0.9 (0.85-0.92) and statistically different values of τ and k between the steps, with p << 0.05. These results indicate that the model is able to describe the HR during walking at different speeds and that its dynamics, in submaximal exercise, is non-linear, since steps of same value presented different responses. |
Keywords: | Engenharia de Produção Frequência cardíaca Modelagem matemática |
Subject CNPq: | CNPQ::ENGENHARIAS::ENGENHARIA DE PRODUCAO |
Program: | Programa de Pós-Graduação em Engenharia de Produção |
Production unit: | Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia |
Publisher: | Universidade Federal do Rio de Janeiro |
Issue Date: | Jul-2017 |
Publisher country: | Brasil |
Language: | por |
Right access: | Acesso Aberto |
Appears in Collections: | Engenharia de Produção |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
877950.pdf | 1.54 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.