Please use this identifier to cite or link to this item: http://hdl.handle.net/11422/12022
Type: Dissertação
Title: Avaliação do efeito da estimulação magnética transcraniana nos sinais de eletroencefalograma usando o Teste F Espectral e a função de coerência
Other Titles: Transcranial magnetic stimulation electroencephalogram signals effects evaluation using Spectral F Test and coherence function
Author(s)/Inventor(s): Massote, Mariana Aguiar
Advisor: Sá, Antonio Mauricio Ferreira Leite Miranda de
Co-advisor: Ichinose, Roberto Macoto
Abstract: Este trabalho realiza um estudo exploratório de sinais de eletroencefalograma (EEG) após estimulação magnética transcraniana (TMS). A TMS é utilizada para diagnóstico e terapia para algumas enfermidades. Porém, há dificuldades em processar o artefato causado pela descarga da TMS. Utilizou-se um estimulador magnético ajustado para pulsos bifásicos com campos de 31 kT de 280 µs de duração, e um aparelho para o registro digital do EEG com 257 canais com um conversor delta-sigma com taxa de amostragem de 20 kHz e registro em 1 kHz. Foram coletados sinais de 12 voluntários sadios, nos quais, inicialmente, aplicou-se o teste F espectral para verificar o efeito da estimulação. Para isso, utilizaram-se quatro janelas de 1s antes e depois do estímulo da TMS. Além disso, propôs-se uma nova forma de avaliação (teste Beta), que utilizou quatro janelas de 1s antes e uma depois do estímulo da TMS, com a finalidade de comparar um trecho mais distante do estímulo e diminuir o efeito do artefato. O teste Beta possui valor crítico analítico e apresenta resultado normalizado, o que facilita a comparação entre voluntários. Os resultados foram consistentes com os da literatura, onde são relatados aumento da potência em frequências até 30 Hz. Todavia, este trabalho considerou um nível de significância de 5%, enquanto outros grupos não apresentaram dados estatísticos utilizados nas análises. Com o teste F, os resultados foram mais baixos que com o teste Beta por este ter mais influência da janela imediatamente após o estímulo que aquele.
Abstract: This work accomplishes an exploratory study of electroencephalogram signals (EEG) after transcranial magnetic stimulation (TMS). TMS is used for diagnosis and as a therapy for some illnesses, but there is difficulty in processing the artifact caused by discharging of TMS. The magnetic stimulator used was adjusted to provide biphasic pulses that lasted 280 µs and magnetic field generated has 31 kT for the biggest intensity point, and a 257-channel EEG recording equipment, which has a delta-sigma converter with a 20000-Hz sampling rate and register of 1000 Hz, was used. The signals were collected from 12 healthy volunteers. Spectral F Test was initially used with 4 one-second windows after the TMS stimulus and 4 one-second windows before the TMS, to check the effect of stimulation. The Beta Test was proposed using 4 onesecond windows before TMS stimulus and one one-second window after TMS, with the goal of comparing a more distant period after the stimulus and hence decreasing the artifact effect. The Beta Test has an analytic critic value and shows normalized result, which makes the volunteers results comparison easier. The results are in accordance with those accomplished by other research groups, in which there is an increase of the frequency potency until 30 Hz. However, this work considered a 5%-significance level, while other groups do not show statistics for the analysis. F Test results were lower than Beta Test, since Beta Test has more influence of the window immediately after the stimulus than the F Test.
Keywords: Estimulação magnética transcraniana
Eletroencefalograma
Teste F Espectral
Subject CNPq: CNPQ::ENGENHARIAS::ENGENHARIA BIOMEDICA
Program: Programa de Pós-Graduação em Engenharia Biomédica
Production unit: Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia
Publisher: Universidade Federal do Rio de Janeiro
Issue Date: Apr-2018
Publisher country: Brasil
Language: por
Right access: Acesso Aberto
Appears in Collections:Engenharia Biomédica

Files in This Item:
File Description SizeFormat 
MarianaAguiarMassote-min.pdf2.87 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.