Title: Caracterização da pele com estrias Albas, in vivo, com ultrassom de alta resolução e rlastografia supersonic shear imaging
Author(s)/Inventor(s): Carvalho, Cátia Pinto
Advisor: Pereira, Wagner Coelho de Albuquerque
Abstract: O Ultrassom de alta resolução (USAR) e a elastografia supersonic shear imaging (SSI) são técnicas não invasivas, não ionizantes e de fácil manuseio empregadas para estudo da pele. Porém, são raras as pesquisas usando os métodos para o estudo da pele com estrias dérmicas (ED). O estudo propôs a utilização do USAR para identificar, in vivo, lesões dérmicas (LD) devido a presença de ED e mensurar as espessuras das camadas sem e com estrias por meio de imagens 2D e da SSI para mensurar e comparar os valores do módulo de Young (E) na pele sem e com ED. Na fase I, imagens 2D da pele sem e com ED de dez voluntários foram usadas para medir e comparar as suas espessuras. Na fase II, elastogramas da pele sem e com ED de onze voluntários foram usados para obter valores de E à 0°, 45°, 90° e 315° às linhas de tensão da pele (LTP). LD apareceram em imagens 2D como áreas pobres de eco. Uma redução estatisticamente significativa na espessura da derme foi encontrada (valor-p <0,05) na presença de EDs. Os valores médios de E em relação à LTPs foram mais elevados na pele normal a 45°(57,72±26,49 kPa) e a 90°(55,40±12,04 kPa) e, com ED, foram também a 45° (40,15±12,26 kPa) e a 90° (38,33±14,36 kPa). O USAR e a SSI mostraram serem técnicas promissoras para o estudo da pele com ED e para avaliar de modo não invasivo protocolos terapêuticos para o tratamento de ED.
Abstract: The High resolution ultrasound (HRUS) and supersonic shear imaging (SSI) elastography are non-invasive, non-ionizing, and easy-to-use methods for analysis of the skin . However, researches are rare using the methods for the study of skin with dermal striae (DS). The study proposed the use of the USAR to identify in vivo dermal lesions (DL) due to the presence of DS and to measure the thicknesses of the skin without and with DS using 2D images and the use of SSI to measure and compare values of Young’s modulus (E) on the skin without and with DS. The work comprised two stages. In phase I, skin 2D images without and with DS of ten volunteers were used to measure and compare their thicknesses. In phase II, skin elastography images without and with DS of the eleven volunteers were used to obtain E values at 0 °, 45 °, 90 °and 315 ° to the skin tension lines (STL). DL caused for DS appeared in 2D images as poor echo areas. A statistically significant reduction in dermis thickness was found (value-p<0.05) in the presence of DS. The mean E values for LTPs were higher in normal skin at 45°(57,72±26,49 kPa) and 90°(55,40±12,04 kPa) and for DS were also at 45° (40,15±12,26 kPa) and 90° (38,33±14,36 kPa). HRUS and SSI have been shown to be promising techniques in the study of the skin with DS and for non-invasive evaluating therapeutic protocols for DS treatment
Keywords: Ultrassom
Elastografia
Estria
Derme
Pele
Subject CNPq: CNPQ::ENGENHARIAS
Program: Programa de Pós-Graduação em Engenharia Biomédica
Production unit: Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia
Publisher: Universidade Federal do Rio de Janeiro
Issue Date: Jun-2019
Publisher country: Brasil
Language: por
Right access: Acesso Aberto
Appears in Collections:Engenharia Biomédica

Files in This Item:
File Description SizeFormat 
CatiaPintoCarvalho.pdf4.51 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.