Please use this identifier to cite or link to this item:
http://hdl.handle.net/11422/13742
Type: | Tese |
Title: | Metodologia para otimização de inspeção em tubos por radiografia digital direta |
Other Titles: | Proposed methodology for optimization of inspection in tubes |
Author(s)/Inventor(s): | Gomes, Célio Simonacci Gomes |
Advisor: | Lopes, Ricardo Tadeu |
Abstract: | A busca por novas metodologias e consequente aprimoramento das técnicas existentes de inspeção são prioridades no processo de melhoria da eficiência de produção na indústria. O objetivo deste estudo foi apresentar uma metodologia destinada a correção de distorções em imagens feitas com detectores digitais planos de soldas circunferenciais em tubos. Foram determinadas as condições que impõem as distorções e as geometrias envolvidas foram descritas matematicamente. Para corrigir esses problemas, foram propostos dois algoritmos construídos com o programa MATLAB. As imagens radiográficas de juntas soldadas de tubos de aço com diferentes diâmetros foram adquiridas utilizando radiografia convencional e detectores do tipo Flat panel. Os defeitos foram medidos e comparados nas imagens feitas com sistema convencional, digital e nas imagens corrigidas pelo algoritmo, bem como indicadores de qualidade de imagem, onde foi observada uma melhora de até 17 vezes na SNRn relativa à maior uniformidade do sinal após a correção. As deformações de nível de cinza e dos defeitos foram corrigidas atingindo precisão de 98% quando comparadas ao padrão. Foi observada uma diminuição de 50% no número de imagens necessárias para análise completa de um tubo de 10 polegadas de diâmetro. |
Abstract: | The search for new methodologies and consequent improvement of existing inspection techniques are priorities in the process of increasing production efficiency in the industry. The objective of this study was to present a methodology for the correction of distortions in images made with Flat panel detectors of circumferential welds in tubes. The conditions that impose the distortions were determined and the geometries involved were mathematically described. To correct these problems, two algorithms constructed with the MATLAB program were proposed. Radiographic images of welded joints of steel tubes with different diameters were acquired using conventional radiography and Flat panel detectors. The defects were measured and compared in the conventional and digital images and in the images corrected by the algorithm, as well as image quality indicators, where an improvement of up to 17 times was observed in the SNRn relative to the higher signal uniformity after correction. The gray level deformations and the defects were corrected reaching 98% accuracy when compared to the standard. A 50% decrease in the number of images required for complete analysis of a 10-inch diameter tube was observed. |
Keywords: | Detectabilidade Descontinuidade Qualidade da imagem Correções de imagem |
Subject CNPq: | CNPQ::ENGENHARIAS::ENGENHARIA NUCLEAR |
Program: | Programa de Pós-Graduação em Engenharia Nuclear |
Production unit: | Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia |
Publisher: | Universidade Federal do Rio de Janeiro |
Issue Date: | Jun-2018 |
Publisher country: | Brasil |
Language: | por |
Right access: | Acesso Aberto |
Appears in Collections: | Engenharia Nuclear |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
CelioSimonacciGomes.pdf | 3.88 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.