Use este identificador para citar ou linkar para este item: http://hdl.handle.net/11422/12024
Tipo: Dissertação
Título: An investigation of the surface electromyograms spatial distribution of the pectoralis major muscle during flat and inclined bench press exercises
Título(s) alternativo(s): Investigação da distribuição espacial dos eletromiogramas de superfície no músculo peitoral maior durante o exercício supino reto e inclinado
Autor(es)/Inventor(es): Mancebo, Felipe Dias
Orientador: Oliveira, Liliam Fernandes de
Coorientador: Vieira, Taian de Mello Martins
Resumo: No primeiro estudo utilizamos a eletromiografia de superfície de alta densidade para investigar a localização da zona de inervação (ZI) no músculo peitoral maior (PM) e o quanto ela se desloca durante o exercício supino. Onze participantes realizaram o exercício isometricamente em duas amplitudes de movimento: com o cotovelo flexionado a 0° e 100°. Os Eletromiogramas (EMGs) foram adquiridos com um vetor de 16 eletrodos posicionado paralelo às fibras do PM. Os deslocamentos na posição da ZI variaram entre 0,5 cm e 3,5 cm. No segundo estudo investigamos a distribuição dos EMGs no PM durante o supino reto e inclinado. Sete indivíduos realizaram duas séries do supino reto e duas do inclinado (45°). Os indivíduos executaram para as duas inclinações, 8 repetições com carga de 70% de uma repetição máxima (1RM) e 15 repetições com 50% de 1RM. O vetor de 16 eletrodos foi posicionado paralelamente ao esterno entre a ZI e a região do tendínea do PM para aquisição dos sinais. O valor médio quadrático (RMS) foi calculado separadamente para cada contração. EMGs com amplitude RMS maior que 70% da amplitude máxima foram definidos como canais ativos. Considerando os canais ativos, a coordenada do baricentro foi calculada indicando a posição média da distribuição RMS ao longo do eixo crânio-caudal do PM. Para todos os voluntários, identificamos que durante o supino inclinado a coordenada do baricentro estava localizada próximo à região clavicular, e para o supino reto estava próxima da região esternocostal.
Resumo: For the first study we use high-density surface electromyography (HD-EMG) to investigate the location of the innervation zone (IZ) on the pectoralis major muscle (PM) and how it displaces during bench press (BP) exercise. Eleven participants performed isometric BP at two conditions: elbow joint flexed at 100° and at 0°. Electromyograms (EMGs) were detected with a dry array of 16 electrodes parallel to the PM fibres. Shifts in IZ position ranged from 0.5 cm to 3.5 cm across all subjects over the detection sites. For the second study, we investigated the distribution of PM activity during the flat and inclined (45°) BP. Seven individuals performed two sets of flat BP and two sets of inclined BP. They used two different load levels, 70% of their one maximum repetition load (1MR) to perform 8 repetitions and 50% of 1MR for 15 repetitions. EMGs activity was recorded with an array of 16 electrodes placed parallel to the sternum and between IZ and PM tendon region. For each contraction, the root mean square (RMS) value was computed. Additionally, active channels were defined as EMGs with RMS amplitude greater than 70% of the maximum amplitude for each contraction. Considering the active channels, the barycentre coordinates were calculated indicating the mean position of the RMS distribution along cranio-caudal axis of PM. For all the volunteers, we identified for the inclined BP that the barycentre was located near to the clavicular region, and for the flat BP it was near to the sternocostal region.
Palavras-chave: Eletromiografia
Peitoral Maior
Treinamento de força
Assunto CNPq: CNPQ::ENGENHARIAS::ENGENHARIA BIOMEDICA
Programa: Programa de Pós-Graduação em Engenharia Biomédica
Unidade produtora: Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia
Editora: Universidade Federal do Rio de Janeiro
Data de publicação: Jun-2018
País de publicação: Brasil
Idioma da publicação: eng
Tipo de acesso: Acesso Aberto
Aparece nas coleções:Engenharia Biomédica

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
FelipeDiasMancebo.pdf1.07 MBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.