Use este identificador para citar ou linkar para este item:
http://hdl.handle.net/11422/13580
Tipo: | Tese |
Título: | Estudo das propriedades de micropartículas de poli(Acetato de vinila-co-metacrilato de metila) usadas em procedimentos de embolização vascular |
Título(s) alternativo(s): | Study of properties of poly(vinyl acetate-co-methyl methacrylate) microparticles for vascular embolization procedures |
Autor(es)/Inventor(es): | Azevedo, Gustavo Dias |
Orientador: | Pinto, José Carlos Costa da Silva |
Resumo: | O uso de polímeros cresceu vertiginosamente em aplicações médicas nos últimos anos, sobretudo nos procedimentos de embolização vascular. O desafio reside em desenvolver agentes embólicos com propriedades morfológicas adequadas para tornar a aplicação segura e reprodutível. Neste contexto, o tamanho de partícula exerce uma enorme importancia sobre o bom desempenho do procedimento de embolização vascular, de maneira que valores fora da faixa de especificação podem gerar problemas tanto para o paciente quanto para o médico. Mais ainda, a distribuição de tamanho de partículas precisa ser bem controlada para evitar a produção de grandes quantidades de material fora de especificação, aumentando os custos do processo. Neste trabalho, estudou-se a influência de algumas técnicas de dispersão previamente descritas na literatura sobre as propriedades das partículas poliméricas produzidas por meio do processo de copolimerização em suspensão, especialmente o tamanho e a distribuição de tamanhos de partículas. Foram avaliados os efeitos exercidos pela aplicação das técnicas separadamente e combinadas, mostrando será possível determinar uma condição ótima de operação, em que as propriedades do material estão mais próximas das desejadas para as aplicações em embolização vascular. |
Resumo: | The use of polymers in medical applications has grown significantly in the past few years, specially in vascular embolization procedures. The challenge is to develop embolic agents with suitable morphological properties in order to make the application safer and reproducible. In this context, the particle size plays a significant role in vascular embolization performance, since off-spec particle diameters may constitute a problem not only for physicians but also for patients. Additionally, the particle size distribution must be controlled in order to avoid the production of large amounts of off-spec material, increasing the process costs. In the present work, the influence of dispersion techniques previously described in literature on properties of polymer particles was evaluated, specially in respect to average particle sizes and particle size distributions. The effects of the analyzed techniques were evaluated independently and combined with other techniques in order to provide an optimum condition, which must be sufficiently close to the desired properties for vascular embolization procedures. Moreover, the hydrolysis of particles were also performed, showing that the extention of the reaction is governed by PMMA composition in the copolymer. |
Palavras-chave: | polimerização em suspensão Distribuição de tamanho de patícula Copolimerização Embolização vascular |
Assunto CNPq: | CNPQ::ENGENHARIAS::ENGENHARIA QUIMICA |
Programa: | Programa de Pós-Graduação em Engenharia Química |
Unidade produtora: | Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia |
Editora: | Universidade Federal do Rio de Janeiro |
Data de publicação: | Fev-2019 |
País de publicação: | Brasil |
Idioma da publicação: | por |
Tipo de acesso: | Acesso Aberto |
Aparece nas coleções: | Engenharia Química |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
GustavoDiasAzevedo-min.pdf | 6.21 MB | Adobe PDF | Visualizar/Abrir |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.