Título : | Desenvolvimento de uma metodologia para equiparação de aceleradores lineares de uso médico utilizando modelagem computacional |
Otros títulos: | Development of a methodology for the equalization of linear accelerators of medical use using computational modeling |
Autor(es)/Inventor(es): | Martins, Carlos Henrique Quintanilha |
Tutor: | Silva, Ademir Xavier da |
Resumen: | O acelerador linear médico se tornou o equipamento predominante em radioterapia, ou seja, em teleterapia. A sua utilização necessita de um contínuo controle de qualidade devido à complexidade, tanto do equipamento quanto do paciente. O processo do cálculo de dose para o tratamento depende de diversos fatores, principalmente da constituição física do acelerador linear. Constantemente pacientes tem seu tratamento interrompido devido a defeitos nestes equipamentos, podendo ter um tempo de reparo considerável. Neste cenário, a interrupção do tratamento por longo tempo é extremamente prejudicial ao paciente, no que concerne a doenças malignas. A solução seria transferir o paciente de um equipamento para outro. Em muitas Instituições Oncológicas, apesar de possuírem mais de um equipamento de tratamento, muitas vezes são de modelos ou fabricantes diferentes, necessitando de modificações trabalhosas nos planejamentos destes pacientes. Portanto, este trabalho vem adicionar uma visão das diferenças de desempenho, em relação a compatibilidade destes equipamentos, através da metodologia de comparação do resultado de suas simulações, por meio da modelagem computacional, utilizando o Método Monte Carlo. |
Resumen: | The medical linear accelerator became the predominant equipment in radiotherapy, that is, in teletherapy. Its use requires continuous quality control due to the complexity of both the equipment and the patient. The process of dose calculation for treatment depends on several factors, mainly the physical constitution of the linear accelerator. Patients constantly have their treatment interrupted due to defects in these equipment, and may have a considerable repair time. In this scenario, discontinuation of treatment for a long time is extremely detrimental to the patient, as regards malignant diseases. The solution would be to transfer the patient from one device to another. In many Oncology Institutions, although they have more than one treatment equipment, they are often from different models or manufacturers, necessitating laborious modifications in the planning of these patients. Therefore, this work comes to add a vision of the differences of performance, in relation to the compatibility of these equipments, through the methodology of comparison of the result of their simulations, through computational modeling, using the Monte Carlo Method. |
Materia: | Acelerador linear Monte Carlo Heterogeneidade |
Materia CNPq: | CNPQ::ENGENHARIAS::ENGENHARIA NUCLEAR |
Programa: | Programa de Pós-Graduação em Engenharia Nuclear |
Unidade de producción: | Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia |
Editor: | Universidade Federal do Rio de Janeiro |
Fecha de publicación: | mar-2018 |
País de edición : | Brasil |
Idioma de publicación: | por |
Tipo de acceso : | Acesso Aberto |
Aparece en las colecciones: | Engenharia Nuclear |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
CarlosHenriqueQuintanilhaMartins.pdf | 8.87 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.