Title: Digital one-cycle control technique with grid voltage measurement applied to three-phase power factor corrected rectifiers and active power filters
Author(s)/Inventor(s): Ferreira, Armando José Gomes Abrantes
Advisor: Rolim, Luís Guilherme Barbosa
Co-advisor: Dias, Robson Francisco da Silva
Abstract: Considerando a demanda por melhorias nas cargas elétricas domésticas e industriais para atender às metas desafiadoras de satisfazer a demanda cada vez maior de energia elétrica e reduzir as emissões de gases de efeito estufa, o presente trabalho visa aplicar o Controle de Um Ciclo Digital (DOCC) com medição de tensão de rede para retificadores de fator de potência corrigida (PFC) e filtro ativo de potência (APF) trifásicos. O uso de tensão de rede é explorado em uma abordagem generalizada, definindo a influência dessas medições nas taxas de distorção harmônicas, fator de potência e limites de operação de carga. A compensação de queda de tensão indutiva e o uso de PWM Híbrido também são aplicados para melhorar o fator de potência e o uso do barramento CC. Resultados de simulação e experimentais da técnica OCC Digital aplicada a retificadores PFC e APF são apresentados, analisados e comparados com resultados experimentais e de simulação de técnicas convencionais para cada sistema.
Abstract: Considering the demand for improvements on domestic and industrial electrical loads to meet challenging goals of keeping up to an ever increasing demand of electri- cal energy and on the reduction of greenhouse gas emissions, the present work aims to apply the Digital One Cycle Control (DOCC) with grid voltage measurement to three-phase Power Corrected (PFC) Rectifier and Active Power Filter (APF). The use of grid voltage is explored in a generalized approach, by defining the influence of these measurements on harmonics, power factor and load limits. The compensation of inductive voltage drop and the use of Hybrid PWM are also applied to improve the power factor and the DC bus usage. Simulation and experimental results of the OCC digital technique applied to PFC and APF rectifiers are presented, analyzed and compared to simulation and experimental results of conventional technique for each system.Também disponível on-line.
Keywords: Controle não-linear
Controle de ciclo
Controle digital
Baixo custo
Subject CNPq: CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA::MEDIDAS ELETRICAS, MAGNETICAS E ELETRONICAS INSTRUMENTACAO::SISTEMAS ELETRONICOS DE MEDIDA E DE CONTROLE
Program: Programa de Pós-Graduação em Engenharia Elétrica
Production unit: Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia
Publisher: Universidade Federal do Rio de Janeiro
Issue Date: Mar-2019
Publisher country: Brasil
Language: eng
Right access: Acesso Aberto
Appears in Collections:Engenharia Elétrica