dc.identifier.citationSANTOS, Raphael Francisco Gomes dos. Influência de blindagens de sala de radioterapia na dose efetiva de pacientes submetidos ao tratamento de câncer de próstata. 2021. 146 f. Tese (Doutorado) - Programa de Pós-Graduação em Engenharia Nuclear, COPPE, Universidade Federal do Rio de Janeiro, Rio de Janeiro, 2021.pt_BR
dc.identifier.urihttp://hdl.handle.net/11422/27245-
dc.description.abstractThis paper presents an analysis of the influence of the shields of the radiotherapy room on the doses received by the organs/tissues adjacent to the target tumor. The development of the work was carried out by computationally simulating a Varian Clinac 2300/CD accelerator (15 MV), a radiotherapy room and an anthropomorphic phantom in voxels. The simulation of the linear accelerator was carried out based on the information of documents provided by the manufacturer Varian and validated, comparing the simulated results to those obtained by the Golden Data issued by the manufacturer. The doses used for throttle validation were obtained at 4x4 cm2 , 10x10 cm2 and 20x20 cm2 openings where the deep dose and lateral dose profiles were evaluated, taking into account the acceptance criteria described in the literature. Subsequently, the influence of shields on equivalent and effective doses was evaluated in a patient undergoing prostate radiotherapy. The addition of steel and lead to shielding showed that the materials contribute in a tiny way to the doses in the patient. The data obtained were compared with the literature, indicating that the dose distribution in tissues adjacent to the tumor is lower with increased energy of the therapeutic beam.pt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal do Rio de Janeiropt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectRadioterapiapt_BR
dc.subjectCâncer de próstatapt_BR
dc.subjectAceleradores linearespt_BR
dc.subjectBlindagem contra radiaçãopt_BR
dc.subjectDosimetria das radiaçõespt_BR
dc.subjectFantomaspt_BR
dc.subjectMétodo de Monte Carlopt_BR
dc.subjectRadiotherapypt_BR
dc.subjectProstate cancerpt_BR
dc.subjectLinear acceleratorspt_BR
dc.subjectRadiation shieldingpt_BR
dc.subjectRadiation dosimetrypt_BR
dc.subjectPhantomspt_BR
dc.subjectMedical imagingpt_BR
dc.subjectMonte Carlo methodpt_BR
dc.titleInfluência de blindagens de sala de radioterapia na dose efetiva de pacientes submetidos ao tratamento de câncer de próstatapt_BR
dc.typeTesept_BR
dc.contributor.advisorLatteshttp://lattes.cnpq.br/5706200091973418pt_BR
dc.contributor.authorLatteshttp://lattes.cnpq.br/6685190450217350pt_BR
dc.contributor.advisorCo1Silva Junior, Wilson Freitas Rebello da-
dc.contributor.advisorCo1Latteshttp://lattes.cnpq.br/5388048554531038pt_BR
dc.contributor.referee1Lima, Inayá Corrêa Barbosa-
dc.contributor.referee1Latteshttp://lattes.cnpq.br/4522339408624972pt_BR
dc.contributor.referee2Medeiros, Marcos Paulo Cavaliere de-
dc.contributor.referee2Latteshttp://lattes.cnpq.br/2847914110054839pt_BR
dc.contributor.referee3Salgado, César Marques-
dc.contributor.referee3Latteshttp://lattes.cnpq.br/9316451931152992pt_BR
dc.contributor.referee4Salata, Camila-
dc.contributor.referee4Latteshttp://lattes.cnpq.br/5605267512779938pt_BR
dc.description.resumoEste trabalho apresenta uma análise da influência das blindagens da sala de radioterapia sobre as doses recebida pelos órgãos/tecidos adjacentes ao tumor alvo. O desenvolvimento do trabalho foi realizado simulando computacionalmente um acelerador Varian Clinac 2300/CD (15 MV), uma sala de radioterapia e um fantoma antropomórfico em voxels. A simulação do acelerador linear foi realizada baseada nas informações de documentos fornecidos pela fabricante Varian e validada, comparando os resultados simulados aos obtidos pelo Golden Data emitido pelo fabricante. As doses utilizadas para validação do acelerador, foram obtidas nas aberturas 4x4 cm2 , 10x10 cm2 e 20x20 cm2 onde os perfis de dose profunda e laterais de dose foram avaliados, levando em consideração os critérios de aceitação descritos na literatura. Posteriormente, foi avaliado a influência das blindagens sobre as doses equivalente e efetiva em um paciente submetido à radioterapia de próstata. A adição do aço e do chumbo ás blindagens mostrou que os materiais contribuem de forma ínfima para as doses no paciente. Os dados obtidos foram comparados com a literatura, indicando que a distribuição da dose nos tecidos adjacentes ao tumor é menor com o aumento da energia do feixe terapêutico.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentInstituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenhariapt_BR
dc.publisher.programPrograma de Pós-Graduação em Engenharia Nuclearpt_BR
dc.publisher.initialsUFRJpt_BR
dc.subject.cnpqCNPQ::ENGENHARIAS::ENGENHARIA NUCLEAR::APLICACOES DE RADIOISOTOPOS::APLICACOES INDUSTRIAIS DE RADIOISOTOPOSpt_BR
dc.embargo.termsabertopt_BR
Appears in Collections:Engenharia Nuclear

Files in This Item:
File Description SizeFormat 
945325.pdf1.91 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.