Please use this identifier to cite or link to this item:
http://hdl.handle.net/11422/27249
| Type: | Tese |
| Title: | Desenvolvimento de metodologias para medição de vazão em dutos de petróleo e derivados usando o radiotraçador 123I |
| Author(s)/Inventor(s): | Gonçalves, Eduardo Ramos |
| Advisor: | Lima, Inayá Corrêa Barbosa |
| Co-advisor: | Brandão, Luís Eduardo Barreira |
| Abstract: | Para garantir a credibilidade das operações de transferência de commodities na indústria de petróleo e gás, medidores de vazão calibrados são usados para quantificar a movimentação de fluidos nos dutos. Tradicionalmente, conforme proposto pela norma ISO 2975-7: 1977 para ensaios em meio aquoso, o Método de Transiente de Tempo (MTT) é empregado para medir vazão posicionando dois detectores separados por distâncias que, em plantas industriais, nem sempre é possível instalá-los em posições recomendadas por essa norma. Como não existe norma específica para medição de vazão de petróleo e seus derivados líquidos com uso de radiotraçadores, o objetivo deste trabalho é propor uma metodologia em que aplica o MTT, usando o óleo marcado com 123I como radiotraçador, com um conjunto de quatro detectores cintiladores NaI(Tl) para medir vazão de petróleo e seus derivados líquidos em dutovias, dutos instalados em plantas industriais ou plantas com espaço restrito, tipicamente encontrados em plataformas. O método proposto neste trabalho utiliza os detectores NaI(Tl) separados um do outro por 0,30 m e três injeções contendo 5,0 ml de óleo marcado com 123I. Os experimentos foram realizados em uma linha de transporte que permitiu escoamentos com perfis de velocidades característicos de regime laminar, de transição e turbulento. os resultados alcançaram incertezas inferiores a 1,0% para escoamentos com Número de Reynolds da ordem de 104. |
| Abstract: | To ensure the credibility of commodity transfer operations in the oil and gas industry, calibrated flow meters are used to quantify fluid movement in pipelines. The use of the Time Transient Method with radiotracers can add logistical and financial advantages to the flow measurement as a function of the properties of the interaction of radiation with matter. Traditionally, as proposed by the ISO 2975-7: 1977 standard for tests in aqueous media, the Time Transient Method is used by placing two detectors separated by distances that, in industrial plants, it is not always possible to install them in positions recommended by this standard. As there is no specific standard for measuring the flow of oil and its liquid derivatives using radiotracers, the objective of this work is to propose a methodology in which the Time Transient Method is applied, using the 123Ilabelled oil as a radiotracer, with a set of four NaI(Tl) scintillating detectors to measure the flow of oil and its liquid derivatives in pipelines, pipelines installed in industrial plants or plants with restricted space, typically found on offshore platforms. The method proposed in this work uses scintillator detectors separated from each other by 0.30 m and three injections containing 5.0 ml of 123I-labelled oil. The experiments were carried out in a transport line that allowed the production of flows with velocity profiles characteristic of laminar, transition and turbulent regimes. the results reached uncertainties lower than 1.0% for flows with a Reynolds number in the order of 104. |
| Keywords: | Radiotraçadores Radioisótopos Petróleo Medição de vazão Dutos Detectores cintiladores Radiotracers Radioisotopes Petroleum products Flow measurement Pipelines Scintillation counters |
| Subject CNPq: | CNPQ::ENGENHARIAS::ENGENHARIA NUCLEAR::APLICACOES DE RADIOISOTOPOS::APLICACOES INDUSTRIAIS DE RADIOISOTOPOS |
| Program: | Programa de Pós-Graduação em Engenharia Nuclear |
| Production unit: | Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia |
| Publisher: | Universidade Federal do Rio de Janeiro |
| Issue Date: | Nov-2021 |
| Publisher country: | Brasil |
| Language: | por |
| Right access: | Acesso Aberto |
| Citation: | GONÇALVES, Eduardo Ramos. Desenvolvimento de metodologias para medição de vazão em dutos de petróleo e derivados usando o radiotraçador 123I. 2021. 127 f. Tese (Doutorado) - Programa de Pós-Graduação em Engenharia Nuclear, COPPE, Universidade Federal do Rio de Janeiro, Rio de Janeiro, 2021. |
| Appears in Collections: | Engenharia Nuclear |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| 953642.pdf | 2.91 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.