Please use this identifier to cite or link to this item: http://hdl.handle.net/11422/8818
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMotta, Andréa Barreira-
dc.contributor.authorPereira, Luiz Carlos-
dc.contributor.authorCunha, Andréia Rosa Coelho Carneiro da-
dc.contributor.authorDuda, Fernando Pereira-
dc.date.accessioned2019-07-15T20:58:45Z-
dc.date.available2023-12-21T03:06:14Z-
dc.date.issued2008-03-27-
dc.identifier.issn0160-564Xpt_BR
dc.identifier.urihttp://hdl.handle.net/11422/8818-
dc.description.abstractStudies pertaining to the mechanical behavior of fixed partial dentures (FPDs) frequently found the highest tensile stress values at the connector region when load is applied at the pontic central region. The connector region is considered the weakest point of the prosthesis with the greatest potential of fractures, regardless of the material used. This 2D finite element study compared the stress distribution on three‐element all‐ceramic and metal‐ceramic FPDs with different loading conditions. Three FPD models were designed: (i) metal‐ceramic FPD; (ii) all‐ceramic FPD with the veneering porcelain only on the occlusal face; and (iii) all‐ceramic FPD with the veneering porcelain on the occlusal and cervical face of the pontic. Loads of 100 N were applied following these simulations: (i) distributed on all working cusps; (ii) only on the abutment teeth; and (iii) only on the pontic. There is a significant change on the stress distribution and on the tensile stress values when the load configuration is changed. The stress distribution from the load applied on the abutments was significantly better compared with the other two load simulations. When the loads were applied on the pontic and distributed on all working cusps, the highest tensile stress values appeared on the cervical region of the connectors between the abutments and the pontic. However, when the load was applied on the abutment teeth, the maximum tensile stress value significantly decreased and was located on the occlusal region of the connectors. In fact, the load applied on the pontic region does not simulate the clinical situation. Studies using this load configuration have overestimated the connector regions as having the highest probability of failures.en
dc.languageengpt_BR
dc.publisherWileyen
dc.relation.ispartofArtificial Organsen
dc.rightsAcesso Abertopt_BR
dc.subjectFinite element analysisen
dc.subjectFixed partial denturesen
dc.subjectStress analysisen
dc.subjectMetal ceramic restorationsen
dc.subjectStress fracturesen
dc.titleThe influence of the loading mode on the stress distribution on the connector region of metal-ceramic and all-ceramic fixed partial denture.en
dc.typeArtigopt_BR
dc.identifier.doi10.1111/j.1525-1594.2008.00544.xpt_BR
dc.description.resumoIndisponível.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentNúcleo Interdisciplinar de Dinâmica dos Fluidospt_BR
dc.subject.cnpqCNPQ::CIENCIAS EXATAS E DA TERRA::FISICA::AREAS CLASSICAS DE FENOMENOLOGIA E SUAS APLICACOES::DINAMICA DOS FLUIDOSpt_BR
dc.citation.volume32pt_BR
dc.citation.issue4pt_BR
dc.citation.spage283pt_BR
dc.citation.epage291pt_BR
dc.embargo.terms365 diaspt_BR
Appears in Collections:Engenharias

Files in This Item:
File Description SizeFormat 
2008_DUDA_AO_v32_p283-291-min.pdf191.13 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.