Please use this identifier to cite or link to this item: http://hdl.handle.net/11422/13730
Type: Tese
Title: Desenvolvimento e caracterização de um sistema automatizado portátil de fluorescência de raios X por reflexão total
Other Titles: Development and characterization of a portable automated total reflection x-ray fluorescence system
Author(s)/Inventor(s): Araújo, Ubiratan Barbosa de
Advisor: Lopes, Ricardo Tadeu
Abstract: Este trabalho apresenta o desenvolvimento e caracterização de um sistema automatizado portátil de fluorescência de raios X por reflexão total (TXRF). O sistema apresenta um arranjo compacto sendo composto por um tubo de raios X de 50 W, com ânodo de molibdênio e um detector Si-PIN, refletores de quartzo, monocromador de lucite, mesas micrométricas e um goniômetro acionadas por motores de passo controlados através do software de programação do Arduino. O sistema foi submetido a testes de verificação do centro geométrico do feixe, variação angular, repetibilidade, curva de sensibilidade, limite de detecção (LD), precisão e acurácia. O sistema teve uma aplicação na análise de amostras de leite bovino coletadas na cidade de Bauru, São Paulo. No teste de repetibilidade, o sistema apresentou um coeficiente de variação igual a 3,5%. A precisão e exatidão foram de aproximadamente de 17% e 7%, respectivamente. O LD observado ficou entre intervalo de 34 g.g -1 a 0,08 g.g -1 (15 ≤ Z ≤ 37). Na análise das amostras de leite bovino foram detectados os elementos: P, S, K, Ca, Mn, Fe, Ni, Cu, Zn, Rb e Sr. Confrontado os resultados quantitativos com o sistema de TXRF pode-se concluir que, os valores obtidos são compatíveis a outras técnicas analíticas utilizadas para análise de leite bovino. O sistema mostrou-se eficiente, provando que é possível produzir fluorescência de raios X com um sistema de alta tecnologia e baixo custo utilizando um tubo de raios X de baixa potência e um detector compacto de Si-PIN.
Abstract: This work presents the development and characterization of a portable automated total reflection X ray fluorescence system (TXRF). The system presents a compact arrangement consisting of a 50 kV X-ray tube with molybdenum anode and a Si-PIN detector, quartz optical flat, lucite monochromator, linear positioners and a goniometer driven by stepper motors controlled through software in programming Arduino. The system was subjected to verification tests of the beam geometric center, angular variation, repeatability, sensitivity curve, limit of detection (LD), precision and accuracy. The system had an application in the analysis of bovine milk samples collected in the city of Bauru, São Paulo. In the repeatability test, the system presented a variation coefficient equal to 3.5%. The precision and accuracy were approximately 17% and 7%, respectively. The LD observed was in the range from 34 g.g -1 to 0.08 g.g -1 (15 ≤ Z ≤ 37). In the analysis of bovine milk samples, the following elements were detected: P, S, K, Ca, Mn, Fe, Ni, Cu, Zn, Rb and Sr. Comparing the quantitative results with the TXRF system, it can be concluded which data are compatible with the technical analyzes used for bovine milk analysis. The system proved to be efficient, proving that it is possible to produce Xray fluorescence with a high-tech, low-cost system using a low-power X-ray tube and a compact Si-PIN detector.
Keywords: Fluorescência de raios X
Reflexão total
Guia de onda
Sistema automatizado
Subject CNPq: CNPQ::ENGENHARIAS::ENGENHARIA NUCLEAR
Program: Programa de Pós-Graduação em Engenharia Nuclear
Production unit: Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia
Publisher: Universidade Federal do Rio de Janeiro
Issue Date: Mar-2018
Publisher country: Brasil
Language: por
Right access: Acesso Aberto
Appears in Collections:Engenharia Nuclear

Files in This Item:
File Description SizeFormat 
UbiratanBarbosaDeAraujo.pdf3.35 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.