Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11422/12796
Especie: Dissertação
Título : Recuperação de ácido succínico através de extração líquido-líquido usando contactor de membrana
Autor(es)/Inventor(es): Antunes, Evelyn Cristine Evangelista da Silva
Tutor: Habert., Alberto Cláudio
Tutor : Kronemberger, Frederico Araujo
Resumen: A extração líquido-líquido (ELL) representa um método de separação promissor para a recuperação primária de ácidos carboxílicos obtidos através de fermentação. O principal objetivo deste trabalho foi investigar o processo de extração assistida por contactores de membrana hidrofílica microporosa (ECM) na recuperação do ácido succínico. Ensaios de extração convencional foram conduzidos para avaliar o efeito de variáveis operacionais (pH e temperatura) na eficiência de extração. Duas configurações para o sistema de ECM foram estudadas: processos de extração e reextração desacoplados e processo simultâneo de extração e reextração. O coeficiente de distribuição (KD) não foi significativamente afetado por variações da temperatura e foi observado o seu aumento com a diminuição do pH. Um modelo matemático para o processo de ECM foi proposto e apontou que, considerando idênticas condições de extração e reextração, quanto menor o valor de KD, maior é a eficiência do processo. Esse comportamento foi verificado experimentalmente através de ensaio utilizando ácido oleico como solvente. A eficiência da etapa de extração do ácido succínico para esse solvente passou de 2,54 % (extração por contato direto) para 50,78% ao utilizar o processo acoplado de extração assistida por contactores de membrana, o que comprova a potencialidade da ELL como método de separação do ácido succínico.
Resumen: Liquid-liquid extraction (ELL) represents a promising separation method for primary recovery of carboxylic acids that are obtained by fermentation. This work aims at investigating the recovery of succinic acid by liquid-liquid extraction assisted by porous membrane contactor (ECM). Conventional extraction tests were carried to evaluate the effect of operational variables (pH and temperature) on extraction efficiency. Two configurations for the ECM system were studied: uncoupled extraction and re-extraction processes (u-ECM) and simultaneous extraction and re-extraction (sECM). The distribution coefficient was not significantly affected by temperature and it increased as pH decreased. A mathematical model for the ECM process was proposed and it indicated that the lower the distribution coefficient, the higher the process efficiency, considering the same exact conditions for extraction and re-extraction. This trend was also experimentally verified. It was found that the s-ECM process increased the extraction efficiency from 2.54% (conventional extraction) to 50.78% using oleic acid as solvent. This demonstrates that liquid-liquid extraction assisted by membrane contactor is a technically feasible separation method for recovery of succinic acid
Materia: Extração líquido-líquido
Contactor de membrana
Materia CNPq: CNPQ::ENGENHARIAS::ENGENHARIA QUIMICA
Programa: Programa de Pós-Graduação em Engenharia Química
Unidade de producción: Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia
Editor: Universidade Federal do Rio de Janeiro
Fecha de publicación: dic-2018
País de edición : Brasil
Idioma de publicación: por
Tipo de acceso : Acesso Aberto
Aparece en las colecciones: Engenharia Química

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
EvelynCristineEvangelistaDaSilvaAntunes-min.pdf1.24 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.