Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/11422/13742
Especie: Tese
Título : Metodologia para otimização de inspeção em tubos por radiografia digital direta
Otros títulos: Proposed methodology for optimization of inspection in tubes
Autor(es)/Inventor(es): Gomes, Célio Simonacci Gomes
Tutor: Lopes, Ricardo Tadeu
Resumen: A busca por novas metodologias e consequente aprimoramento das técnicas existentes de inspeção são prioridades no processo de melhoria da eficiência de produção na indústria. O objetivo deste estudo foi apresentar uma metodologia destinada a correção de distorções em imagens feitas com detectores digitais planos de soldas circunferenciais em tubos. Foram determinadas as condições que impõem as distorções e as geometrias envolvidas foram descritas matematicamente. Para corrigir esses problemas, foram propostos dois algoritmos construídos com o programa MATLAB. As imagens radiográficas de juntas soldadas de tubos de aço com diferentes diâmetros foram adquiridas utilizando radiografia convencional e detectores do tipo Flat panel. Os defeitos foram medidos e comparados nas imagens feitas com sistema convencional, digital e nas imagens corrigidas pelo algoritmo, bem como indicadores de qualidade de imagem, onde foi observada uma melhora de até 17 vezes na SNRn relativa à maior uniformidade do sinal após a correção. As deformações de nível de cinza e dos defeitos foram corrigidas atingindo precisão de 98% quando comparadas ao padrão. Foi observada uma diminuição de 50% no número de imagens necessárias para análise completa de um tubo de 10 polegadas de diâmetro.
Resumen: The search for new methodologies and consequent improvement of existing inspection techniques are priorities in the process of increasing production efficiency in the industry. The objective of this study was to present a methodology for the correction of distortions in images made with Flat panel detectors of circumferential welds in tubes. The conditions that impose the distortions were determined and the geometries involved were mathematically described. To correct these problems, two algorithms constructed with the MATLAB program were proposed. Radiographic images of welded joints of steel tubes with different diameters were acquired using conventional radiography and Flat panel detectors. The defects were measured and compared in the conventional and digital images and in the images corrected by the algorithm, as well as image quality indicators, where an improvement of up to 17 times was observed in the SNRn relative to the higher signal uniformity after correction. The gray level deformations and the defects were corrected reaching 98% accuracy when compared to the standard. A 50% decrease in the number of images required for complete analysis of a 10-inch diameter tube was observed.
Materia: Detectabilidade
Descontinuidade
Qualidade da imagem
Correções de imagem
Materia CNPq: CNPQ::ENGENHARIAS::ENGENHARIA NUCLEAR
Programa: Programa de Pós-Graduação em Engenharia Nuclear
Unidade de producción: Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia
Editor: Universidade Federal do Rio de Janeiro
Fecha de publicación: jun-2018
País de edición : Brasil
Idioma de publicación: por
Tipo de acceso : Acesso Aberto
Aparece en las colecciones: Engenharia Nuclear

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
CelioSimonacciGomes.pdf3.88 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.