Please use this identifier to cite or link to this item: http://hdl.handle.net/11422/8288
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLamien, Bernard-
dc.contributor.authorOrlande, Helcio Rangel Barreto-
dc.contributor.authorVarón, Leonardo Antonio Bermeo-
dc.contributor.authorBasto, Rodrigo Leite Queiroga-
dc.contributor.authorEliçabe, Guillermo Enrique-
dc.contributor.authorSantos, Dilson Silva dos-
dc.contributor.authorCotta, Renato Machado-
dc.date.accessioned2019-06-04T18:39:21Z-
dc.date.available2023-12-21T03:05:57Z-
dc.date.issued2018-09-11-
dc.identifier.issn1464-5157pt_BR
dc.identifier.urihttp://hdl.handle.net/11422/8288-
dc.description.abstractBackground: One of the challenges faced during the hyperthermia treatment of cancer is to monitor the temperature distribution in the region of interest. The main objective of this work was to accurately estimate the transient temperature distribution in the heated region, by using a stochastic heat transfer model and temperature measurements. Methods: Experiments involved the laser heating of a cylindrical phantom, partially loaded with iron oxide nanoparticles. The nanoparticles were manufactured and characterized in this work. The solution of the state estimation problem was obtained with an algorithm of the Particle Filter method, which allowed for simultaneous estimation of state variables and model parameters. Measurements of one single sensor were used for the estimation procedure, which is highly desirable for practical applications in order to avoid patient discomfort. Results: Despite the large uncertainties assumed for the model parameters and for the coupled radiation– conduction model, discrepancies between estimated temperatures and internal measurements were smaller than 0.7 C. In addition, the estimated fluence rate distribution was physically meaningful. Maximum discrepancies between the prior means and the estimated means were of 2% for thermal conductivity and heat transfer coefficient, 4% for the volumetric heat capacity and 3% for the irradiance. Conclusions: This article demonstrated that the Particle Filter method can be used to accurately predict the temperatures in regions where measurements are not available. The present technique has potential applications in hyperthermia treatments as an observer for active control strategies, as well as to plan personalized heating protocols.en
dc.languageengpt_BR
dc.publisherTaylor & Francispt_BR
dc.relation.ispartofInternational Journal of Hyperthermiaen
dc.rightsAcesso Abertopt_BR
dc.subjectState estimationen
dc.subjectParticle filteren
dc.subjectMonte Carloen
dc.subjectNanoparticlesen
dc.titleEstimation of the temperature field in laser-induced hyperthermia experiments with a phantomen
dc.typeArtigopt_BR
dc.identifier.doi10.1080/02656736.2018.1496283pt_BR
dc.description.resumoIndisponível.pt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentNúcleo Interdisciplinar de Dinâmica dos Fluidospt_BR
dc.subject.cnpqCNPQ::CIENCIAS EXATAS E DA TERRA::FISICA::AREAS CLASSICAS DE FENOMENOLOGIA E SUAS APLICACOES::DINAMICA DOS FLUIDOSpt_BR
dc.citation.volume35pt_BR
dc.citation.issue1pt_BR
dc.citation.spage279pt_BR
dc.citation.epage290pt_BR
dc.embargo.termsabertopt_BR
Appears in Collections:Engenharias

Files in This Item:
File Description SizeFormat 
13-2018_Estimation-of-the-temperature-field--min.pdf893.23 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.