Vigas parede em concreto leve com e sem furos
Carregando...
Arquivos
Data
Autores
Título da Revista
ISSN da Revista
Título de Volume
Editor
Universidade Federal do Rio de Janeiro
DOI
Resumo
The present paper reports the results of an experimental investigation on the behavior of lightweight concrete deep beams up to failure. Nine (9) simply supported deep beams, with and without web openings, were tested under symmetrical two-point loading Each beam had a 2.00 m span, an overall depht of 1.00 m and a thickness of 0,10 m. The amount of web reinforcement was varied to study its influence on the failure load. The experimental values of the failure load were compared with theoretical ones obtained with the application of
the CEB-FIP Recommendations, the ACI Building Code, the Truss Analogy proposed by Kumar and the formulae proposed by Kong. Based on the observed behavior of the tested beams it was also applied the theory of Plasticity to obtain their failure load.
Dans cette étude on présente les résultats d'une
recherche expérimentale sur le comportement, jusqu'à la rupture,
des poutres cloison en béton léger armé. On a essayé 9 (neuf) poutres cloison avec et sans
ouverture. Les poutres, sur deux appuis simple, avaient 2,00 m
de portée, 1,00 m d'hauteur et 0,10 m d'épaisseur et deux charges
concentrées ont été appliquées dans les ticer de la portée.
On a varié le pourcentage géometrique d'armature et on a etudié
son influence sur la charge de rupture. Les valeurs expérimentales des charges de rupture
ont été confrontées aux valeurs théoriques obteneus des
Recommandations du CEB-FIP, des normes de l'ACI, de l'analogie
du treillis proposée par KUMAR et des formules proposée
par KONG. Basé sur le comportement des modéles essayés, on a
appliqué la theorie de la plasticité pour obtenir les charges
de rupture des poutres cloison.
Descrição
Palavras-chave
Citação
Coleções
Avaliação
Revisão
Suplementado Por
Referenciado Por
Direitos e licensiamento
Acesso Aberto